Instrument sets and hospital logistics in joint replacement

Published:

The role of system-specific instrument sets in knee and hip replacement surgery, the cycle by which a set reaches the hospital and how responsibilities are divided.

When people think of knee or hip replacement surgery, they usually think of the implant itself. Yet on the operating table there is another component that matters just as much: the surgical instrument set designed for that implant system. This article gives a general overview of what instrument sets are for in joint replacement surgery, how sets reach the hospital and who is responsible for what along the way.

Why every implant system has its own set

Every implant system is designed with its own dimensions and geometry. To shape the bone so that the implant fits, the cuts, angles and cavities have to be prepared to suit that system. This is why manufacturers design system-specific instruments alongside their implants. Instruments for one system are generally not used with another, and the surgical technique is described in terms of these instruments.

What a set contains

Set contents vary from system to system, but the instrument groups commonly found in knee and hip replacement sets are:

  • Alignment instruments: guide rods and measuring instruments that help make the bone cuts at the correct angle relative to the axis of the leg.
  • Cutting blocks: blocks that keep the saw on the planned plane. In knee replacement, the femoral and tibial cuts are made with these blocks.
  • Rasps and reamers: in hip replacement, rasps prepare the canal of the thighbone to the shape of the stem, and hemispherical reamers shape the acetabulum to the size of the cup.
  • Trial components: temporary parts with the same dimensions as the final implant. The surgeon uses them to check the movement and balance of the joint before deciding on the implant size.
  • Insertion instruments: holders and impactors that help seat the implant in the correct position in the bone.

For a joint replacement operation, these instruments are usually spread across several trays. Each tray comes with a content list showing where each instrument belongs.

Pre-operative planning and size range

Before surgery, the surgeon may estimate the expected implant size by templating on X-ray images. The final size, however, is determined during surgery with the trial components. This is why not just a single size but the sizes around the expected one are brought to the operation. For systems with components specific to the left or right side, planning the correct side matters just as much.

Implants and instruments: two separate processes

Implants usually arrive from the manufacturer in sterile packaging and are single-use; the package is opened only in surgery, at the moment of use. Instruments, by contrast, are reusable. After every use they have to be cleaned, inspected, packed and sterilised again.

This reprocessing is the hospital's responsibility and is carried out in the hospital's sterile services department under the institution's own procedures. The process is described in detail in guidance published by organisations such as the World Health Organization (WHO) and the U.S. Centers for Disease Control and Prevention (CDC). The manufacturer's instructions for use also contain information on how the instruments should be cleaned and sterilised.

The journey of a set to surgery

Implant sets are often not kept at every hospital at all times; they are brought in for a planned operation and collected afterwards. In general, the cycle consists of these steps:

  • Planning: the date of surgery, the joint and side to be operated on, the system to be used and the expected size range are confirmed with the hospital.
  • Preparation: the instrument trays are checked against their content lists; the required implant sizes are set aside.
  • Delivery: the set is delivered in time for the hospital's sterile services department to complete its process.
  • Surgery: with the hospital's permission and at its request, the distributor's technical staff may support the surgical team with information on the instruments and products. Clinical decisions always rest with the surgeon.
  • Collection and records: after surgery the set is collected once the hospital has cleaned and decontaminated it; its contents are checked again and the lot and serial details of the implants used are recorded.

The record in the last step is part of medical device traceability. We cover this topic separately in our article on medical device traceability.

Separation of responsibilities

Roles in this process are clearly separated. The physician decides which treatment a patient receives and which implant is used. Reprocessing and sterilisation of the instruments is the hospital's responsibility. The distributor is responsible for delivering products and sets on time, complete and documented, for keeping track of set contents and for passing on accurate product information.

EM-TU Sağlık's set management and technical support services for Chunli Medical and Just Medical systems are described on the services page; for your hospital's needs, you can reach us through the contact page.

Sources

This article is for general information only; in practice, the applicable regulations and institutional procedures apply.

Write to us about products or documents

Tell us your institution and the system you are interested in; a product specialist will get back to you.