Hip replacement components and types of fixation

Published:

An overview of the stem, head, acetabular cup and liner of a hip replacement, bearing surface pairings and cemented, cementless and hybrid fixation.

The hip is a ball-and-socket joint. The rounded head at the upper end of the thighbone (femur) sits in a cup-shaped socket in the pelvis (the acetabulum). As in the knee, these surfaces are covered with cartilage. When the cartilage wears, or in a situation such as a hip fracture, the physician may discuss hip replacement surgery (hip arthroplasty) as one of the options based on their assessment.

In a hip replacement, the damaged femoral head and the surface of the acetabulum are replaced with parts that mimic the ball-and-socket structure of the joint. This article gives a general overview of the components of a hip replacement system, the material pairings used for the bearing surfaces and the ways the components are fixed to bone.

Total hip replacement and hemiarthroplasty

In a total hip replacement, both sides of the joint are replaced: a stem and head are fitted on the femoral side and a cup on the pelvic side. In a hemiarthroplasty (partial hip replacement), only the femoral side is replaced and the head of the implant moves within the patient's own acetabulum. Some hemiarthroplasty designs use a single-piece head, while bipolar designs have a second moving surface inside the head.

Components of a hip replacement

Femoral stem

A metal part inserted into the inner canal of the thighbone. The length, cross-section and neck angle of stems vary by design. At the top of the stem there is a tapered connection onto which the femoral head is fitted.

Femoral head

A spherical part that takes the place of the natural femoral head. It may be metal or ceramic. In most systems the head is attached to the stem as a separate part (modular design), so the surgeon can choose between different head diameters and neck lengths.

Acetabular cup

A hemispherical part placed in the socket of the pelvis. In most designs it consists of an outer metal shell. Some cups have holes through which screws can be passed for additional hold in the bone. The outer surface of cups used without cement is roughened or porous so that bone can attach to it.

Liner

The part placed inside the shell, in which the femoral head turns. It may be polyethylene, ceramic or metal. Together, the femoral head and the liner form the bearing surface of the joint. Some polyethylene liner models have a raised edge on one side to make it harder for the head to come out of the socket.

Bearing surface pairings

The materials of the femoral head and the liner are considered together. Commonly described pairings are:

  • Metal head and polyethylene liner
  • Ceramic head and polyethylene liner
  • Ceramic head and ceramic liner
  • Metal head and metal liner: a group that regulators monitor separately; the U.S. Food and Drug Administration (FDA) publishes a dedicated information page on metal-on-metal hip implants.

In addition, dual mobility designs are used, in which a polyethylene part moves both inside the metal shell and around the femoral head. The choice of pairing is determined by the patient's condition and the surgeon's assessment.

Types of fixation

Hip replacement components are fixed to bone using three basic approaches:

  • Cemented fixation: bone cement (polymethyl methacrylate) is applied between the component and the bone; once the cement hardens, it holds the component in place.
  • Cementless fixation: the component is fitted tightly into the bone (press-fit). Its surface is porous or coated, and over time bone grows onto this surface and holds the component. The acetabular cup can also be supported with screws if needed.
  • Hybrid fixation: one component is cemented and the other is not; for example, a cemented femoral stem with a cementless acetabular cup.

The surgeon chooses the fixation method taking into account factors such as bone quality, the structure of the bone and the implant system to be used. For this reason, implant systems may offer different models of the same component for cemented and cementless use.

Modularity and sizes

Hip replacement systems are offered as a family with different stem sizes, neck angles, head diameters and cup dimensions. One of these options is offset: the horizontal distance between the centre of the femoral head and the axis of the stem. Different offset and neck options help the surgeon bring the geometry of the joint closer to the patient's anatomy. During surgery the surgeon uses trial components to check the movement of the joint, leg length and joint stability, and then decides on the size of the actual implants. We describe the components of a knee replacement in our knee replacement article.

EM-TU Sağlık distributes Chunli Medical and Just Medical hip replacement systems in Türkiye. These systems are listed on the hip products page, and the manufacturers' catalogs are on the catalogs page.

Sources

This article is for general information only; diagnosis and treatment decisions rest with the physician.

Write to us about products or documents

Tell us your institution and the system you are interested in; a product specialist will get back to you.