What is a knee replacement and what are its components
Published:
A general overview of the femoral, tibial, insert and patellar components of a knee replacement, CR and PS designs and the ways they are fixed.
The knee is the joint where the lower end of the thighbone (femur), the upper surface of the shinbone (tibia) and the kneecap (patella) meet. The surfaces where these bones touch are covered with articular cartilage, which lets the bones glide smoothly over one another. When the cartilage wears or is damaged, the physician may discuss different treatment options based on their assessment. One of these options is knee replacement surgery (knee arthroplasty).
In a knee replacement, the worn joint surfaces are removed and replaced with metal and plastic parts. Despite the name, the procedure is usually not a replacement of the whole knee but a resurfacing of the bone ends. This article gives a general overview of the parts that make up a knee replacement system and the main differences between designs.
Total and partial knee replacement
The knee is functionally divided into three compartments: the inner (medial) compartment, the outer (lateral) compartment and the patellofemoral compartment behind the kneecap. In a total knee replacement, all the joint surfaces of the thighbone and shinbone are covered with implant parts. In a partial (unicompartmental) knee replacement, only one compartment is resurfaced. The physician decides which approach is suitable, taking into account factors such as where the joint is damaged and the condition of the ligaments.
Components of a knee replacement
A total knee replacement system usually consists of four main components. Each component is made in several sizes, so the surgeon can choose parts that match the patient's bone dimensions.
Femoral component
A curved metal part fitted to the lower end of the thighbone. Its shape mimics the rounded joint surfaces of the bone (the condyles). At the front there is a groove in which the kneecap glides.
Tibial component
A metal base plate (tibial tray) that sits on the flattened top of the shinbone. The underside of the tray may carry a stem or pegs that help it hold in the bone. Its upper side carries the plastic spacer.
Insert (plastic spacer)
A part made of medical-grade polyethylene, placed between the femoral component and the tibial tray. It keeps the metal surfaces from rubbing directly against each other and forms the gliding surface of the joint. Inserts come in different thicknesses; the surgeon chooses the thickness according to the balance of the knee during surgery. Plastic does not show up clearly on an X-ray the way metal parts do, so on an X-ray there appears to be a gap between the two metal components.
Patellar component
A dome-shaped plastic part fitted to the back of the kneecap. It is not used in every operation: the surgeon decides whether or not to resurface the kneecap.
CR and PS designs
Inside the knee there are two cruciate ligaments that connect the thighbone and the shinbone. In total knee replacement the anterior cruciate ligament is usually removed. For the posterior cruciate ligament there are two basic design approaches:
- Cruciate-retaining (CR) design: the posterior cruciate ligament is left in place and continues to stabilise the bones as the knee moves.
- Posterior-stabilised (PS) design: the posterior cruciate ligament is removed. Its role is taken over by a raised post in the middle of the insert and a matching structure (the cam) on the femoral component; as the knee bends, the two come into contact and limit sliding of the bones.
There are also designs in which the insert is locked to the tibial tray (fixed bearing) and designs in which it can rotate to a limited extent on the tray (mobile bearing). Which design is used depends on the condition of the ligaments, the structure of the joint and the surgeon's assessment.
How the components are fixed to bone
The metal components are attached to bone in two basic ways. In cemented fixation, bone cement (polymethyl methacrylate) is applied between the bone and the implant. In cementless fixation, the part is fitted tightly into the bone (press-fit); the specially treated surface of the component allows bone to grow onto it over time. In some operations the two methods are combined (hybrid). The surgeon makes the choice.
Sizes, trial components and instruments
A knee replacement system is not made of implants alone. Cutting blocks that guide the bone cuts at the correct angle, measuring instruments and trial components of the same dimensions as the final implants are also part of the system. The surgeon checks the movement and balance of the knee with the trial components before deciding on the size of the actual implants. This is why every system is used with its own instrument set. Preparing the sets for surgery is a separate logistics process, which we describe in our article on surgical sets and logistics.
EM-TU Sağlık is the Türkiye distributor of Chunli Medical and Just Medical knee and hip replacement systems. The knee replacement systems we distribute are listed on the knee products page.
Sources
- American Academy of Orthopaedic Surgeons (AAOS), OrthoInfo: Total Knee Replacement (external site)
- NHS: Knee replacement (external site)
This article is for general information only; diagnosis and treatment decisions rest with the physician.